- Inspect
- Installed heating and cooling systems
- Readily openable access panels
- Central and through-the-wall systems
- “Ductless Mini-Split” systems
- Visible and readily accessible portions of associated distribution systems, flues, and chimneys
- Describe
- Heating system(s)
- Cooling system(s)
- Energy source(s)
- Distribution system(s)
- Basic Delta-T readings measured at supply and return air registers (compressor-based systems)
- Not required
- Inspection of any system without power, fuel supply turned off, winterized, or shut down by local utility company or service specialist
- Operate any system except with normal controls
- Operate cooling system if outdoor temperature is below 65° F
- Adequacy of heat supply, cooling supply, or distribution balance
- Interiors of flues or chimneys that are not readily accessible
- Any portion of a compressor-based system that is not readily accessible
- Heat exchangers
- Humidifiers or dehumidifiers
- Electronic or ultraviolet filtration systems
- Solar or solar-hybrid heating systems
- Window or portable AC units